Chapter 1 general information – TDK 2U GENESYS 5KW User Manual

Page 14

background image

83-515-000 Rev. B

6

CHAPTER 1 GENERAL INFORMATION

1.1 USER MANUAL CONTENT

This User’s Manual contains the operating instructions, installation instructions and specifications of
the Genesys

TM

5000W power supply series. The instructions refer to the standard power supplies,

including the built-in RS232/RS485 serial communication. For information related to operation with the
optional IEEE programming, refer to User Manual for Power Supply IEEE Programming Interface.

1.2 INTRODUCTION

1.2.1

General Description

Genesys

TM

power supplies are wide output range, high performance switching power supplies. The

Genesys

TM

series is power factor corrected and operates from AC voltage range of 190-240VAC

three phase for 200V models and 380-415VAC three phase for 400VAC models. Output Voltage and
Current are continuously displayed and LED indicators show the complete operating status of the
power supply. The Front panel controls allow the user to set the output parameters, the protections
levels (Over-Voltage protection, Under-Voltage limit and Foldback) and preview the settings. The rear
panel includes the necessary connectors to control and monitor the power supply operation by remote
analog signals or by the built-in serial communication (RS232/RS485).GPIB programming, LXI certi-
fied LAN and Isolated-Analog programming/monitoring are optional.

1.2.2

Models covered by this Manual
Models with rated output from 0-8VDC/0-600A to 0-600VDC/0-8.5A.

Model

Voltage range
(V)

Current
range (A)

GEN 8 – 600

0 - 8

0 - 600

GEN 10 - 500

0 - 10

0 - 500

GEN 16 - 310

0 - 16

0 - 310

GEN 20 - 250

0 - 20

0 - 250

GEN 30 - 170

0 - 30

0 - 170

GEN 40 - 125

0 - 40

0 - 125

GEN 60 - 85

0 - 60

0 - 85

GEN 80 - 65

0 - 80

0 - 65

GEN 100 - 50

0 - 100

0 - 50

GEN 150 - 34

0 - 150

0 - 34

GEN 300 - 17

0 - 300

0 - 17

GEN 600 - 8.5

0 - 600

0 - 8.5

1.2.3

Features and options

 Constant Voltage / Constant Current with automatic crossover.

 Active power factor correction.

 Embedded Microprocessor Controller.

 Built-in RS232/485 Interface.

 Voltage & Current high resolution adjustment by digital encoders.

 High accuracy programming/readback-16 bit.

 Software Calibration (no internal trimmers / potentiometers).

 Last Setting Memory.

 Independent Remote ON/OFF (opto-isolated) and remote Enable/Disable.

 Parallel operation (Master/Slave) with Active current sharing.

 Remote sensing to compensate for voltage drop of power leads.

 External Analog Programming and Monitoring standard (0-5V or 0-10V, user selectable).