CHAPTER 1 GENERAL INFORMATION
1.1 USER MANUAL CONTENT
This User’s Manual contains the operating instructions, installation instructions and specifications of
the Genesys
TM
5000W power supply series. The instructions refer to the standard power supplies,
including the built-in RS232/RS485 serial communication. For information related to operation with the
optional IEEE programming, refer to User Manual for Power Supply IEEE Programming Interface.
1.2 INTRODUCTION
1.2.1
General Description
Genesys
TM
power supplies are wide output range, high performance switching power supplies. The
Genesys
TM
series is power factor corrected and operates from AC voltage range of 190-240VAC
three phase for 200V models and 380-415VAC three phase for 400VAC models. Output Voltage and
Current are continuously displayed and LED indicators show the complete operating status of the
power supply. The Front panel controls allow the user to set the output parameters, the protections
levels (Over-Voltage protection, Under-Voltage limit and Foldback) and preview the settings. The rear
panel includes the necessary connectors to control and monitor the power supply operation by remote
analog signals or by the built-in serial communication (RS232/RS485).GPIB programming, LXI certi-
fied LAN and Isolated-Analog programming/monitoring are optional.
1.2.2
Models covered by this Manual
Models with rated output from 0-8VDC/0-600A to 0-600VDC/0-8.5A.
Model
Voltage range
(V)
Current
range (A)
GEN 8 – 600
0 - 8
0 - 600
GEN 10 - 500
0 - 10
0 - 500
GEN 16 - 310
0 - 16
0 - 310
GEN 20 - 250
0 - 20
0 - 250
GEN 30 - 170
0 - 30
0 - 170
GEN 40 - 125
0 - 40
0 - 125
GEN 60 - 85
0 - 60
0 - 85
GEN 80 - 65
0 - 80
0 - 65
GEN 100 - 50
0 - 100
0 - 50
GEN 150 - 34
0 - 150
0 - 34
GEN 300 - 17
0 - 300
0 - 17
GEN 600 - 8.5
0 - 600
0 - 8.5
1.2.3
Features and options
Constant Voltage / Constant Current with automatic crossover.
Active power factor correction.
Embedded Microprocessor Controller.
Built-in RS232/485 Interface.
Voltage & Current high resolution adjustment by digital encoders.
High accuracy programming/readback-16 bit.
Software Calibration (no internal trimmers / potentiometers).
Last Setting Memory.
Independent Remote ON/OFF (opto-isolated) and remote Enable/Disable.
Parallel operation (Master/Slave) with Active current sharing.
Remote sensing to compensate for voltage drop of power leads.
External Analog Programming and Monitoring standard (0-5V or 0-10V, user selectable).