TDK 2U GENESYS 5KW User Manual
Page 38
83-515-000 Rev. B
30
Table 4-1: Front Panel Controls and Indicators (continued)
Number
Control/Indicator
Description
Section
15
PREV indicator
Green LED, lights when PREV button is pressed
16
FINE button
Voltage and Current Fine/Coarse adjustment control.
Operates as a toggle switch. In Fine mode, the
VOLTAGE and CURRENT encoders operate with high
resolution and in Coarse mode with lower resolution
(approx. 6 turns).
Auxiliary function: Advanced Parallel Operation Mode
setting.
5.15.2
17
FINE indicator
Green LED, lights when the unit is in Fine mode.
18
ALARM indicator
Red LED, blinks in case of fault detection. OVP, OTP
Foldback, Enable and AC fail detection will cause the
ALARM LED to blink.
19
AC Power switch
AC On/Off control.
4.3 REAR PANEL CONNECTIONS AND CONTROLS
See Fig.4-2 to review the connections and controls located on the power supply rear panel. Refer to
Table 4-2 for explanations about the rear panel connections and controls.
Table 4-2: Rear panel connections and controls
Number
Item
Description
Section
1
AC input
connector
Header w/ a screw plug connector (Phoenix contact PC6-1614-
GF-10, 16).
3.7
2
DC output
Bus-bars for 8V to 100V models.
Wire clamp connector for 150V to 600V models.
3.9.6
3
Remote-In
connector
RJ-45 type connector, used for connecting power supplies to
RS232 or RS485 port of computer for remote control purposes.
When using several power supplies in a power system, the first
unit Remote-In is connected to the computer and the remaining
units are daisy-chained, Remote-In to Remote-Out.
7.3
7.4