TYPICAL SUPPLY CURRENT CHARACTERISTICS FOR TMS320C25

170

160

150

140

130

120

110

100

90

80

70

60

50

40

30

10

20

4

8 12 16 20 24 28 32 36 40 44 48 52

T

A

= 25

C

I

CC

vs f

(CLKIN)

and V

CC

Normal Operating Mode

f

(CLKIN)

, MHz

V

CC

= 5.50 V

V

CC

= 5.25 V

V

CC

= 5.00 V

V

CC

= 4.75 V

V

CC

= 4.50 V

Im

A

CC,

0

80

70

60

50

40

30

10

20

4

8 12 16 20 24 28 32 36 40 44 48 52

I

CC

vs f

(CLKIN)

and V

CC

Powerdown Mode

f

(CLKIN)

, MHz

Im

A

CC,

V

CC

= 5.50 V

V

CC

= 5.25 V

V

CC

= 5.00 V

V

CC

= 4.75 V

V

CC

= 4.50 V

TMS320C25FNL (PLCC) reflow soldering precautions

Recent tests have identified an industry-wide problem experienced by surface mounted devices exposed to

reflow soldering temperatures. This problem involves a package cracking phenomenon sometimes

experienced by large (e.g., 68-lead) plastic leaded chip carrier (PLCC) packages during surface mount

manufacturing. This phenomenon occur if the TMS320C25FNL is exposed to uncontrolled levels of humidity

prior to reflow solder. This moisture can flash to steam during solder reflow, causing sufficient stress to crack

the package and compromise device integrity. If the TMS320C25FNL is being socketed, no special handling

precautions are required. In addition, once the device is soldered into the board, no special handling precautions

are required.
In order to minimize moisture absorption, TI ships the TMS320C25FNL in “dry pack” shipping bags with a RH

indicator card and moisture-absorbing desiccant. These moisture-barrier shipping bags will adequately block

moisture transmission to allow shelf storage for 12 months from date of seal when stored at less than 60%

relative humidity (RH) and less than 30C. Devices may be stored outside the sealed bags indefinitely if stored

at less than 25% RH and 30C.
Once the bag seal is broken, the devices should be stored at less than 60% RH and 30C as well as reflow

soldered within two days of removal. In the event that either of the above conditions is not met, TI recommends

these devices be baked in a clean oven at 125C and 10% maximum RH for 24 hours. This restores the devices

to their “dry packed” moisture level.

NOTE

Shipping tubes will not withstand the 125

C

baking process. Devices should be transferred to a metal tray or tube be-

fore baking. Standard ESD precautions should be followed.

In addition, TI recommends that the reflow process not exceed two solder cycles and the temperature not

exceed 220C.
If you have any additional questions or concerns, please contact your local TI representative.