beautypg.com

3. outdoor unit (rav-sm800at-e) – Toshiba RAV-SM800XT-E User Manual

Page 8

background image

2-3. Outdoor Unit (RAV-SM800AT-E)

365

17.5

17.5

21

21

40

70

29

90

191

20

40

39

47

43

43

95

300

150

60

26

Knockout
(For draining)

Knockout
(For draining)

Drain hole (Ø20 x 88 burring hole)

Drain hole (Ø25 burring hole)

Part A

Part B

(Long hole pitch

for anchor bolt)

Suction
port

Suction

port

Discharge

port

Z

1

2

67

60

264

565

101

154

900

27

60

96

307

300

314

Handles
(Both sides)

Refrigerant pipe connecting port
(Ø9.5 flare at liquid side)

Refrigerant pipe connecting port
(Ø15.9 flare at gas side)

Discharge guide
mounting hole
(4-Ø4 embossing)

1

1

2

2

795

85

165

60

80

25

60

90

320

28

400

161

58

46

30

45

27

Space required for service

365

600

2-Ø12 x 17 U-shape holes
(For Ш8–Ш10 anchor bolt)

Suction port

Discharge
port

Discharge

port

(Minimum
distance up to wall)

2-Ø12 x 17 long hole
(For Ш8–Ш10 anchor bolt)

500

or more

150

or more

150

or more

150 or more

58

7

86

7

Knockout for lower piping

Z views

17.5

40

40

17.5

Installation bolt hole
(Ø12 x 17 U-shape holes)

Installation bolt hole
(Ø12 x 17 U-shape holes)

Details of B part

Details of A part

– 6 –