5-2. Outdoor Unit (RAV-SM560AT-E)
5. SPECIFICATION OF ELECTRICAL PARTS
5-1. Indoor Unit
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
AFP-220-50-4A
Output (Rated) 50 W, 220 – 240 V
2
Grille motor
MP35EA12
DC 12 V
3
Thermo. sensor (TA-sensor)
550 mm
10 k
Ω
at 25
°
C
4
Heat exchanger sensor (TC-sensor)
∅
6 mm, 500 mm
10 k
Ω
at 25
°
C
5
Heat exchanger sensor (TCJ-sensor)
∅
6 mm, 500 mm
10 k
Ω
at 25
°
C
No.
Parts name
Type
Specifications
1
Fan motor
ICF-140-43-1
Output (Rated) 40 W
2
Compressor
DA130A1F-23F
3 phase, 4P, 1100 W
3
Reactor
CH-57
1=10 mH, 16A
4
Outdoor temp. sensor (To-sensor)
—
10 k
Ω
at 25
°
C
5
Heat exchanger sensor (Te-sensor)
—
10 k
Ω
at 25
°
C
6
Suction temp. sensor (Ts-sensor)
—
10 k
Ω
at 25
°
C
7
Discharge temp. sensor (Td-sensor)
—
50 k
Ω
at 25
°
C
8
Fuse (Switching power (Protect))
—
T3.15 A, AC 250 V
9
Fuse (Inverter, input (Current protect)
—
25 A, AC 250 V
10
4-way valve solenoid coil
STF-0108G
11
Compressor thermo. (Protection)
US-622
ON : 90 ± 5
°
C, OFF : 125 ± 4
°
C
5-3. Outdoor Unit (RAV-SM800AT-E)
No.
Parts name
Type
Specifications
1
Fan motor
ICF-140-63-1
Output (Rated) 63 W, 220 – 240 V
2
Compressor
DA220A2F-20L
3 phase, 4P, 1600 W
3
Reactor
CH-47
4
Outdoor temp. sensor (To-sensor)
—
10 k
Ω
at 25
°
C
5
Heat exchanger sensor (Te-sensor)
—
10 k
Ω
at 25
°
C
6
Suction temp. sensor (Ts-sensor)
—
10 k
Ω
at 25
°
C
7
Discharge temp. sensor (Td-sensor)
—
50 k
Ω
at 25
°
C
8
Fuse (Switching power (Protect))
—
T3.15 A, AC 250 V
9
Fuse (Inverter, input (Current protect)
—
25 A, AC 250 V
10
4-way valve solenoid coil
DKV-M0ZS743B0
11
Compressor thermo. (Protection)
US-622
ON : 90 ± 5
°
C, OFF : 125 ± 4
°
C