Indoor unit outdoor unit – Toshiba RAV-SM800XT-E User Manual
Page 10
![background image](/manuals/213228/10/background.png)
– 8 –
3-2. RAV-SM800XT-E / RAV-SM800AT-E
Indoor unit
Outdoor unit
TCJ
sensor
Air heat exchanger
Strainer
Strainer
TC sensor
Refrigerant pipe
at liquid side
Outer dia.
∅
B
Refrigerant pipe
at gas side
Outer dia.
∅
A
Packed valve
Outer dia.
∅
B
Packed valve
Outer dia.
∅
A
Max
50m
TS sensor
Accumulator
(1500cc)
TD sensor
TO sensor
TE
sensor
4-way valve
(STF-0213Z)
∅
25 x L160
Rotary compressor
(DA220A2F-20L)
Heat exchanger
∅
8
1 row 30 stages
FP1.3 flat fin
Modulating (PMV)
(SKV-18D26)
Capillary
∅
3 x
∅
2
x L530
∅
25 x L210
Muffler
R410A 1.5 kg
Cooling
Heating
Ps
Pd
Pressure
Pipe surface temperature (
°
C)
(MPa)
Discharge
Suction
Indoor heat Outdoor heat
Indoor
exchanger
exchanger
fan
Pd
Ps
(TD)
(TS)
(TC)
(TE)
Indoor
Outdoor
Standard
3.3
0.9
89
8
8
40
64
HIGH
27/19
35/–
Cooling
Overload
3.7
1.1
87
17
14
46
45
HIGH
32/24
43/–
Low load
1.0
0.8
22
2
1
1
24
LOW
18/15.5
–5/–
Standard
3.3
0.6
93
0
54
0
70
HIGH
20/–
7/6
Heating
Overload
3.1
1.1
75
20
52
15
24
LOW
30.–
24/18
Low load
2.0
0.2
90
–26
25
–25
90
HIGH
0
–20/(70%)
Indoor/Outdoor
temp. conditions
(DB/WB) (
°
C)
Compressor
revolutions
per second
(rps)
*
* 4 poles are provided to this compressor.
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
Outer diameter of refrigerant pipe
Gas side
∅
A
Liquid side
∅
B
9.5 mm
15.9 mm