Installation procedure, Troubleshooting, Under ceiling installation) – Toshiba RAV-SM800XT-E User Manual
Page 29: Console installation)
– 27 –
9. INSTALLATION PROCEDURE
Remark per EMC Directive 89/336/EEC
To prevent flicker impressions during the start of the compressor (technical process) following installation
conditions do apply.
1. The power connection for the air conditioner has to be done at the main power distribution. This distribution
has to be of an impedance.
Normally the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max.!
2. No other equipment should be connected to this power line.
3. For detailed installation acceptance, please contact your power supplier whether its restriction does apply
for products like washing machines, air conditioners or electrical ovens.
4. For power details of the air conditioner, refer to the rating plate of the product.
9-1. Installation Diagram of Indoor and Outdoor Units
Air filter
9
Filter frame
7
Zeolite filter
8
Purifying filter
Insulate the refrigerant pipes
separately with insulation, not
together.
Min 6 mm thick heat resisting
polyethylene foam
Before install the wireless
remote controller
•
With the remote controller cover
open, load the batteries supplied
correctly, observing their polarity.
%
%
%
%
%
Wireless remote controller
!
!
!
!
!
Batteries
Cover
Pipe shield
(Under Ceiling Installation)
70 m
m or m
ore
200 mm or more
200
m
m o
r m
ore
200 m
m
or m
ore
4
Mounting
screw
(Console Installation)
1
Installation plate
Hook
70
m
m
or m
o
re
200 m
m
or m
ore
#
Pan head wood screw
"
Remote controller holder
%
Wireless remote controller