beautypg.com

10. final installation checks – Toshiba RAV-SM800XT-E User Manual

Page 45

background image

– 43 –

PRE.D

FILTER

Hi POWER

9-10. FINAL INSTALLATION CHECKS

9-10-1. Precautions

Ensure that the electrical cable used for power supply
and control of the system is unable to come into
contact with either service valves or piping work which
are not insulated.

9-10-2. Electrical wiring

When installation is complete, check that all power
supply and interconnecting wiring has been
appropriately protected.

9-10-3. Refrigerant piping

When refrigerant and drain piping have been
completed. Ensure that all pipework is fully insulated
and apply finishing tape to seal the insulation.

9-10-4. Check and Test Operation

Pressure of R410A is approx. 1.6 times of that of
R22. If installation work is incompletely finished, a
gas leakage may occur at the cases such as
pressure rise during operation.
Therefore, be sure to test the piping connections for
leakage.

Check the flare nut connections, valve stem cap
connections and service port cap fittings for gas
leak with a leak detector or soap water.

Fig. 9-10-1

Flare nut
connections
(Indoor unit)

Piping cover

Cord clamp

Indoor/Outdoor
connecting
cables

Power cable

Valve cover

9-10-5. Test Operation

To switch the TEST RUN (COOL) mode, press
TEMPORARY button for 10 sec.
(The beeper will make a short beep.)

Fig. 9-10-2

TEMPORARY
button

9-10-6. Auto Restart Setting

This product is designed so that, after a power failure,
it can restart automatically in the same operating
mode as before the power failure.

Information

The product was shipped with Auto Restart
function in the off position. Turn it on as required.

Press and hold the TEMPORARY button for about
3 seconds. After 3 seconds, the electronic beeper
makes three short beeps to tell you the Auto Restart
has been selected.

To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function of
the Owner’s Manual.

This manual is related to the following products: