12 – other functions, Confidence monitoring – Tascam HS-4000 User Manual
Page 88
88
TASCAM HS-4000
12 – Other functions
Confidence monitoring
During recording, the recorded audio can be read back right
away from the media and output for monitoring.
1.
Press the MENU key on the front panel to open the
MENU
screen.
2.
Touch the
REC SETUP
button to open the
REC SETUP
screen.
3.
Touch the
Confidence
Monitor
ON
button to enable
the confidence monitoring function (default:
ON
).
Confidence monitoring operation conditions
To use the confidence monitoring function, the following
settings are necessary.
Fs (sampling frequency): 44.1k, 48k, 48k–0.1% or 48+0.1k
TIMELINE Rec Tracks: 2tr (in timeline mode)
Number of tracks armed for recording (in take mode):
No more than 2 total
NOTE
・ Set the Fs item when creating a project, and set the TIMELINE Rec Tracks
item when creating a session (or when creating a project for the first
session). These cannot be changed after the creation of a project or
session.
・ When using confidence monitoring, the playback sound is delayed
about 2.4 seconds before output.
・ When a region (take) is divided or the recording region (take) reaches the
maximum size, the confidence monitoring playback sound will be
interrupted for a few seconds.