beautypg.com

Toshiba E-STUDIO 3511 User Manual

Page 277

background image

275

12

4

Remove the empty staple case and
replace it with a new one.

- Replace both staple cases with new ones.

5

Return the saddle staple to its original
position.

- Pull the handle of the saddle stitch holder (1) toward you and turn

it (2) 90º in the direction of the arrow.

6

Return the saddle stitch unit to its original
position.

7

Make sure that LD, LG or LT-R paper is set.

- If any of the above paper sizes is not set, test stapling cannot be

performed.

8

Close the front cover of the finisher. Then,
test stapling is automatically performed
on a blank sheet.

- This is performed to avoid empty stitching.

If there is a test stapling failure and “Check staple cartridge”
remains, repeat the above procedure from step 1 to 8.

(1)

(2)