3 writing a new sms to storage, Writing a new sms to storage, At+cmgw="" Page 66
Page 66
GE863-GPS Software User Guide
1vv0300724 Rev. 2 - 24/01/07
3.5.3 Writing a New SMS to storage
A new SMS can be written in the selected storage
supported) and then can be sent to the desired destination.
To write the new SMS:
•
send command
AT+CMGW="
where:
wait for prompt "
>
"
•
•
•
•
send SMS text (MAX 160 characters)
end command with CTRL-Z character (0x1A hexadecimal) or abort command with ESC character
(0x1B hexadecimal)
wait for response:
Response
Reason
Action
+CMGW:
OK
Message has been successfully
written in position number
proceed ahead
ERROR
some error occurred
Enable the extended error
codes report (see par.2.5.2.1)
and retry.
+CMS ERROR: 330
SMSC address unknown
Insert SMSC address (see par.
3.5.1.3)
+CMS ERROR: 322
Memory Full
memory is full, hence delete
some records and retry.
NOTE: if command is aborted with ESC character, then only the OK result code is returned.
For example:
1- Let's assume you want to write a new SMS to the storage and the destination address is the
number +39338123456789. We suppose you already have set up the device for text SMS mode as
described on the previous paragraphs:
command:
AT+CMGW="+39338123456789"
response:
>
now you can insert the message text in IRA format (note that the IRA format and ASCII format
coincide for the alphabet characters but not for the other).
…. here will be inserted the SMS message text….
conclude text with the character CTRL-Z
response:
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 66 of 109