Temco DV5200 Series

78674

Clearance to Combustibles

Top of unit to ceiling* ................................36” (914 mm)
Front of unit to combustibles ....................36” (914 mm)
Appliance

Top (from standoffs) ................................0” (0 mm)

Bottom .....................................................0” (0 mm)

Side (from standoffs) ................................0” (0 mm)

Back (from standoffs) ...............................0” (0 mm)

Top of Elbow ..........................................2” (51 mm)

* Ceiling height is the minimum height of the room ceiling in front of
the fireplace measured from the top front edge of the fireplace.

Combustible Sidewall Clearance

The perpendicular combustible sidewall or mantel sup-
port leg (surround) clearance is 1³⁄₄” (45 mm) from the
edge of the recessed door opening.

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel.
For the correct mounting height and widths, refer to
Figure 5.
Noncombustible mantels and legs may be installed at
any height and width around the appliance. When using
paint or lacquer, it must be heat resistant to prevent
discoloration.

A B C D E

V

W

X

Y

Z

Fireplace

T177

Temco DV Mantel

Chart

12/3/03 djt

Top of Louvre

Opening

Mantel Chart

Mantel Shelf

Mantel from Top

Ref. or Breast Plate Ref. of Louvre Opening

Depth

V

10” (254 mm)

A

12” (305 mm)

W

8” (203 mm)

B

10¹⁄₂” (267 mm)

X

6” (152 mm)

C

9” (229 mm)

Y

4” (101 mm)

D

7¹⁄₂” (191 mm)

Z

2” (51 mm)

E

5” (127 mm)

T177

Fig. 5 Combustible mantel minimum installation.

WARNING: Combustible objects must not be placed
on a noncombustible mantel unless the noncombustible
mantel meets the minimum height and width require-
ments for a combustible mantel.

Surround Material

When using materials around the face of the fireplace,
these materials must be suitable to withstand the tem-
peratures which they will encounter. Also these materi-
als must not extend out in front of the face of the unit, in
effect recessing the unit.
If the material used for surround is not flush with the
face of the unit, then the optional surround kits will not
fit properly.
It is recommended that any material used to surround
the face of the fireplace be noncombustible (i.e. ceram-
ic tile, brick, natural stone, etc.). Combustible materials
such as drywall, are permissible.

T178

surround material

12/3/03 djt

Drywall

Tile, Marble, etc.

Drywall

Fireplace

Front

Tile,

Marble,

etc.

Optional

Surround

Kits

Fireplace

Front

Noncombustible Facing

Material Overlap of Front Face

Flush Face Installation

(Recommended when

installing optional trim

surround kits)

T178

Fig. 6 Surround material options.

T179

firplace installation

12/3/03 djt

Combustible Material

2 x 4 Stud

2 x 4 Header

Standoff

Minimum Height from

Top Opening to Mantel

Combustible Material

Above Standoff

Optional Hearth

T179

Fig. 7 Gas fireplace installation.

Materials such as cultured marble or other synthetic
materials are not recommended as they may discolor,
warp or create odor as a result of exposure to the tem-
peratures of the front of the fireplace.