Fuel Conversion

WARNING: This Hi/Lo conversion kit must ONLY be
applied as part of a conversion kit supplied by the
appliance manufacturer for the specific appliance
and type of gas being converted.
The conversion shall be carried out in accordance
with the requirements of the provincial authori-
ties having jurisdiction and in accordance with the
requirements of the CSA B149.2 installation code
(Canada) and with the requirements of the Na-
tional Fuel Gas Code ANSI Z223.1/NFPA 54 (United
States).
WARNING: This conversion kit shall be installed
by a qualified service agency in accordance with
the manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in this instruction is
not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified
service agency is responsible for the proper instal-
lation of this kit. The installation is not proper and
complete until the operation of the converted appli-
ance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Installer Notice: Using an ink pen, fill out the re-
quired information on the conversion label. Remove
the backing from the label and stick the label in a
visible position on the bottom of the fireplace close
to the gas valve.
Installer Notice: These instructions must be left
with the appliance.
Instructions for converting your fireplace from Natural
gas to Propane/LP gas.
All fireplaces are shipped from the factory equipped to
operate on Natural gas. To convert the fireplace to op-
erate on Propane/LP gas, follow the instructions below.
Please see the appropriate parts list for your model for
parts included with the fireplace.
Check the items in the kit with the parts list. Notify the
supplier of any items that are missing before installing
the conversion kit.

T205

Dv burner

fuel conversion

1/8/04 djt

1/8” When Gas Tight

Burner

Orifice

Holding Tabs

T205

Fig. 39 Bend holding tabs down and forward.

T206

Dv burner

bend tabs

1/8/04 djt

Bend Down Tabs

Remove Burner Orifice

T206

Fig. 40 Move burner tube to replace orifice.

1. Turn off the gas supply.
2. Turn off the electrical supply to the appliance if so

equipped.

To Replace Burner Orifice

1. Remove lava rock to expose screws and remove

grate assembly.

2. Use screwdriver and bend holding tabs down and

forward. (Fig. 39 & 40)

T207

air shutter

setting

1/8/04 djt

7/16” (11 mm)

T207

Fig. 41 Air shutter settings for propane/LP gas.

Conversion Parts Inluded with Fireplace

Description

Part Number

Orifice 1.45 mm (Main Burner)-LP

PCOA070H37

Label, Conversion

77740

Pilot, Orifice - LP

76263

Conversion Pressure

Regulator Assy - LP

74655

Label SIT Valve

--

3. Move the burner to the left and off the burner orifice.

(Fig. 40)

4. Using a suitable tool, replace natural orifice #44 with

propane orifice 1.45 mm furnished with conversion
kit. Tighten orifice with suitable tool until gas tight.
(Fig. 39)

5. Move burner back to original position tight to orifice

and bend tabs back up.

6. Set the air shutter opening for the corresponding

gas used. (Fig. 41 and Chart on Page 33)