Quantum Sun StorEdge L100 User Manual
Page 139
Appendix B Fault Symptom Code (FSC) Dictionary
Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide
123
2413
FSC_LIBRARIAN_SRC_
ABSENT
Source slot not present
(magazine or drive
removed)
Microcode
100%
2414
FSC_LIBRARIAN_NO_
START_SLOT
Demo unable to select
random start slot (try
re-running demo)
Microcode
100%
2415
FSC_LIBRARIAN_
AUTOCLEAN_IN_
PROGRESS
Move medium
attempted to drive that
is being auto cleaned
Microcode
100%
2416
FSC_LIBRARIAN_BAD_
MESSAGE_PARAMETER
Bad parameter in
Librarian message
Microcode
100%
2417
FSC_LIBRARIAN_
DEDICATED_CLEANER
Fixed slot reserved for
dedicated cleaner; not
for general use
Microcode
100%
2418
FSC_LIBRARIAN_
ROBOT_NOT_READY
Requested action can
not be performed;
robot is busy or in use
Microcode
100%
2419
FSC_LIBRARIAN_
ILLEGAL_MAG_
INSERTED
Magazine 5 present in
6 drive, 7 magazine
configuration
Microcode
100%
241A
FSC_LIBRARIAN_NON_
HOMOGENOUS_STACK
Stack contains
modules configured
for different media to
stack-master
Microcode
100%
2500
FSC_SCSI_NO_
RESOURCE
SCSI task initialization
failed
Microcode
100%
2501
FSC_SCSI_BAD_
MESSAGE
SCSI task received a
bad message
Microcode
100%
2502
FSC_SCSI_QUEUE_FULL
SCSI queue full
Microcode
100%
2503
FSC_SCSI_NO_FAS366
FAS366 not detected
Servo/SCSI
100%
FSC
Name
Description
FRU Name
Confidence %