beautypg.com

Quantum Sun StorEdge L100 User Manual

Page 130

background image

Appendix B Fault Symptom Code (FSC) Dictionary

114

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

1000

FSC_FPGA_INIT_

STUCK_HI

FPGA INIT pin was

detected as being high

when it should have

been low

System

100%

1001

FSC_FPGA_INIT_NOT_

HI

FPGA INIT pin was

detected as being low

when it should have

been high

System

100%

1002

FSC_FPGA_DONE_

STUCK_HI

FPGA DONE pin was

detected as being high

when it should have

been low

System

100%

1003

FSC_FPGA_DONE_NOT_

HI

FPGA DONE pin was

detected as being low

when it should have

been high

System

100%

2000

FSC_DLT_INIT_FAILED

DLT initialization

failed

Microcode

100%

2001

FSC_DRIVE_TIMEOUT_1

Drive time out waiting

for status (drive 1)

Drive

100%

2002

FSC_DRIVE_TIMEOUT_2

Drive time out waiting

for status (drive 2)

Drive

100%

2003

FSC_DRIVE_TIMEOUT_3

Drive time out waiting

for status (drive 3)

Drive

100%

2004

FSC_DRIVE_TIMEOUT_4

Drive time out waiting

for status (drive 4)

Drive

100%

2005

FSC_DRIVE_TIMEOUT_5

Drive time out waiting

for status (drive 5)

Drive

100%

2006

FSC_DRIVE_TIMEOUT_6

Drive time out waiting

for status (drive 6)

Drive

100%

FSC

Name

Description

FRU Name

Confidence %

This manual is related to the following products: