Quantum Sun StorEdge L100 User Manual
Page 136
Appendix B Fault Symptom Code (FSC) Dictionary
120
Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide
2102
FSC_I2C_NO_
ACKNOWLEDGEMENT
No acknowledge
received from slave
I
2
C
100%
2103
FSC_I2C_UNABLE_TO_
SEND_MESSAGE
Exceeded retry limit
while trying to send
message
I
2
C
100%
2104
FSC_I2C_NO_
RESPONSE_FROM_
HARDWARE
Expected response
from hardware was not
received
I
2
C
100%
2105
FSC_I2C_UNKNOWN_
MESSAGE_
DESTINATION
Message received from
I
2
C bus but destination
is unknown
I
2
C
100%
2106
FSC_I2C_MESSAGE_
TOO_BIG
Message to send over
I
2
C bus is too big (see
path)
I
2
C
100%
2107
FSC_I2C_RCV_
MESSAGE_TOO_BIG
Message received over
I
2
C bus is too big
I
2
C
100%
2108
FSC_I2C_MAILBOX_
FULL
I
2
C mailbox is full
I
2
C
100%
2109
FSC_I2C_INVALID_RCV_
ADDRESS
Receiver address in I
2
C
message incorrect
I
2
C
100%
210A
FSC_I2C_STUCK_
INTERRUPT
Pending interrupt
status not reset
I
2
C
100%
2200
FSC_UI_NO_RESOURCE
UI task initialization
failed
Microcode
100%
2201
FSC_UI_QUEUE_FULL
UI queue full
Microcode
100%
2202
FSC_UI_ACTION_
IMPOSSIBLE
The UI is not in the
correct state to perform
the requested action
Microcode
100%
FSC
Name
Description
FRU Name
Confidence %