Appendix B Fault Symptom Code (FSC) Dictionary

120

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

2102

FSC_I2C_NO_

ACKNOWLEDGEMENT

No acknowledge

received from slave

I

2

C

100%

2103

FSC_I2C_UNABLE_TO_

SEND_MESSAGE

Exceeded retry limit

while trying to send
message

I

2

C

100%

2104

FSC_I2C_NO_

RESPONSE_FROM_

HARDWARE

Expected response

from hardware was not

received

I

2

C

100%

2105

FSC_I2C_UNKNOWN_

MESSAGE_

DESTINATION

Message received from

I

2

C bus but destination

is unknown

I

2

C

100%

2106

FSC_I2C_MESSAGE_

TOO_BIG

Message to send over

I

2

C bus is too big (see

path)

I

2

C

100%

2107

FSC_I2C_RCV_

MESSAGE_TOO_BIG

Message received over

I

2

C bus is too big

I

2

C

100%

2108

FSC_I2C_MAILBOX_

FULL

I

2

C mailbox is full

I

2

C

100%

2109

FSC_I2C_INVALID_RCV_

ADDRESS

Receiver address in I

2

C

message incorrect

I

2

C

100%

210A

FSC_I2C_STUCK_

INTERRUPT

Pending interrupt

status not reset

I

2

C

100%

2200

FSC_UI_NO_RESOURCE

UI task initialization

failed

Microcode

100%

2201

FSC_UI_QUEUE_FULL

UI queue full

Microcode

100%

2202

FSC_UI_ACTION_

IMPOSSIBLE

The UI is not in the

correct state to perform

the requested action

Microcode

100%