245

5. Activation

phase

[( Definition format )]

Numeric

value

[( Definition range )]

0 to 0x7FFFFFFF

[( Default value )]

None

Define the activation phase of the cyclic handler. The time representing this startup phase must be defined in ms
units.

6. Start

Address

[( Definition format )]

Symbol or Function Name

[( Definition range )]

None

[( Default value )]

None

Define the start address of the cyclic handler.

Note that the function name defined here will have the declaration statement shown below output to the ker-
nel_id.h file.

#pragma CYCHANDLER /V4 function name

7. Extended

information

[( Definition format )]

Numeric

value

[( Definition range )]

0 to 0xFFFFFFFF

[( Default value )]

0

Define the extended information of the cyclic handler. This information is passed as argument to the cyclic han-
dler when it starts.


[( Alarm handler definition )]
This definition is necessary to use Alarm handler function.

<< Format >>


// Alarm Handlar Definition
alarm_hand[

ID No.

]{

name

=

ID name

;

entry_address

=

Start address

;

exitf

=

Extended information

;

};

:

:

The ID number must be in the range of 1 to 255. The ID number can be omitted.

If omitted, numbers are automatically assigned sequentially beginning with the smallest.

<< Content >>

Define the following for each alarm handler ID number.

1. ID

name

[( Definition format )]

Symbol

[( Definition range )]

None

[( Default value )]

None

Define the name by which the alarm handler is specified in a program.