Operations Commands
Operations commands allow more flexible and direct control of the projector. The syntax
for operations commands is as follows:
op
(Precede
The command type can be one of 5 functions:
Table 6-2 lists the valid operations commands. For all but Execute functions, the response
from the projector is the command and “=
“NA” if the value is not available. For Execute functions the response is the same
command. All responses are in UPPERCASE.
Some operations command examples:
Input:
op bright ? [CR]
Response:
OP BRIGHT = 100 [CR]
Input:
op bright + [CR]
Response:
OP BRIGHT = 101 [CR]
Input:
op bright = 127 [CR]
Response:
OP BRIGHT = 127 [CR]
Input:
op bright - [CR]
Response:
OP BRIGHT = 126 [CR]
Input:
op resync [CR]
Response:
OP RESYNC [CR]
0x10
(none)
The projector does not respond to this key.
0x13
(none)
The projector does not respond to this key.
(none)
(none)
Activates remote backlighting when pressed.
Table 6-1. Serial Command Key Names and IR Codes (continued)
IR Code
RS232
Keyname
Remote Button
Description
ZOOM
LENS
LIGHT
➤
Operations Control Commands
Function
Command
Description
Set
=
Assigns that value to the parameter.
Get
?
Returns the current value of that parameter.
Increment
+
Adds 1 to the current value.
Decrement
-
Subtracts 1 from the current value.
Execute
(none)
Performs an action such as a reset.