Maintenance and Troubleshooting

72

Q-750i Series Installation/Operation Manual

PRE

L

IMINAR

Y

RGB-HD images appear
“noisy.”

• Tracking and Phase

settings need adjustment.

• Manually adjust Tracking

and Phase settings (refer
to Fine Sync on page 59).

LED is flashing red.

• Q-750i internal

temperature is too high
(Note).

• Power off the Q-750i and

allow it to cool down.
Ensure that the intake and
exhaust vents are not
blocked. Turn the
projector back on. If the
problem persists, please
contact Runco Technical
Support for assistance.

LED lights solid red.

• Fans are not working

properly or power-on
self-test has failed (Note).

• Power off the Q-750i and

allow it to cool down. Turn
the projector back on. If
the problem persists,
please contact Runco
Technical Support for
assistance.

Table 5-1. Troubleshooting Chart (continued)

Symptom

Possible Cause(s)

Solution

Note: You can obtain more detailed information about the cause of the error condition using