Brightness, Contrast, 3. typical pluge pattern for adjusting brightness – Runco QUANTUM COLOR Q-750I User Manual

Page 67: 4. typical gray bar pattern for adjusting contrast, Pre l iminar y

background image

Operation

Q-750i Series Installation/Operation Manual

51

PRE

L

IMINAR

Y

Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an
acronym for “Picture Line-Up Generation Equipment.”) Figure 4-3 shows a typical PLUGE
pattern.

Figure 4-3. Typical PLUGE Pattern for Adjusting Brightness

PLUGE patterns vary but generally consist of some combination of black, white and gray
areas against a black background. The example above includes two vertical bars and four
shaded boxes.

Select Brightness from the Main menu. Use the

or

buttons to adjust the level so that:

• The darkest black bars disappear into the background.

• The dark gray areas are barely visible.

• The lighter gray areas are clearly visible.

• The white areas are a comfortable level of true white.

• The image contains only black, gray and white (no color).

Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the
one shown in Figure 4-4.

Figure 4-4. Typical Gray Bar Pattern for Adjusting Contrast

Select Contrast from the Main menu. Use the

or

buttons to adjust the contrast up

until the top two bars become almost the same brightness, then down just until the
brightness change between these bars is consistent with the other bars.

Below Black