187 midi implementation appendices, Universal realtime system exclusive messages, Data transmission – Roland XP-30 User Manual
Page 187
187
MIDI Implementation
Appendices
●
Universal Realtime System Exclusive messages
❍
Master Volume
status
data byte
status
F0H
7FH, 7FH, 04H, 01H, llH, mmH
F7H
Byte
Remarks
F0H
Exclusive status
7FH
ID number
(Universal Realtime message)
7FH
device ID
(Broadcast)
04H
sub ID#1
(Device Control Message)
01H
sub ID#2
(Master Volume)
llH
LSB of Master Volume
mmH
MSB of Master Volume
F7H
EOX
(End Of Exclusive)
*
LSB of Master Volume (llH) is processed as 00H.
*
This message is not received if the Rx.Exc parameter (SYSTEM/MIDI/SYS-EXC MIDI) is
OFF.
*
This message is not received in GM mode.
●
Data Transmission
This instrument can use exclusive messages to exchange many varieties of internal settings
with other devices.
The model ID of the exclusive messages used by this instrument is 6AH.
❍
Data Request 1 RQ1
This message requests the other device to transmit data. The address and size indicate the
type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it is able to
transmit data, and if the address and size are appropriate, the requested data is transmitted
as a Data Set 1 (DT1) message. If the conditions are not met, nothing is transmitted.
status
data byte
status
F0H
41H, dev, 6AH, 11H, aaH, bbH,
F7H
ccH, ddH, ssH, ttH, uuH, vvH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
(Roland)
dev
device ID
(dev: 10H - 1FH)
6AH
model ID
(XP-30)
11H
command ID
(RQ1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
ssH
size MSB
ttH
size
uuH
size
vvH
size LSB
sum
checksum
F7H
EOX
(End Of Exclusive)
*
The size of data that can be transmitted at one time is fixed for each type of data. and
data requests must be made with a fixed starting address and size. Refer to the address
and size given in
*
For the checksum, refer to (p. 204).
*
This message is not received if the Rx.Exc parameter (SYSTEM/MIDI/SYS-EXC MIDI) is
OFF.
*
This message is not received in GM mode.
❍
Data Set 1 DT1
This message transmits the actual data, and is used when you wish to set the data of the
receiving device.
status
data byte
status
F0H
41H, dev, 6AH, 12H, aaH, bbH,
F7H
ccH, ddH, eeH, ... ffH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
(Roland)
dev
device ID
(dev: 10H - 1FH)
6AH
model ID
(XP-30)
12H
command ID
(DT1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
eeH
data:
The actual data to be transmitted. Multi-byte
data is transmitted in the order of the address.
:
:
ffH
data
sum
checksum
F7H
EOX
(End Of Exclusive)
*
The amount of data that is transmitted at one time is fixed for the type of data, and only
data of the fixed starting address and size will be transmitted. Refer to the address and
size given in
*
Data whose size is greater than 128 bytes should be divided into packets of 128 bytes or
less and transmitted. Successive “Data Set 1” messages should have at least 20 ms of
time interval between them.
*
For the checksum, refer to (p. 204).
*
This message is not received if Rx.Exc parameter (SYSTEM/MIDI/SYS-EXC MIDI) is
OFF.
*
This message is not received in GM mode.
This device is able to receive GS Exclusive messages only for Scale Tune settings.
❍
Data Set 1 DT1
This message transmits the actual data, and is used when you wish to set the data of the
receiving device.
status
data byte
status
F0H
41H, dev, 42H, 12H, aaH, bbH,
F7H
ccH, ddH, ... eeH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
(Roland)
dev
device ID
(dev: 10H - 1FH)
42H
model ID
(GS)
12H
command ID
(DT1)
aaH
address MSB
bbH
address middle byte
ccH
address LSB
ddH
data:
The actual data to be transmitted. Multi-byte
data is transmitted in the address order.
:
:
eeH
data
sum
checksum
F7H
EOX
(End Of Exclusive)
*
This message is not received when the Rx.Exc parameter (SYSTEM/MIDI/SYS-EXC
MIDI) is OFF.
*
This message is not received in GM mode.