Mount the hardware, Mounting the server, Prerequisites – Nortel Networks Application Server 53r 5300 00 User Manual
Page 23
Mount the hardware
23
Table 6
IBM x3550 hardware characteristics (cont’d.)
Item
Description
Server identification
x3550, Model 7978 AC1
CPU
2 x Quad-Core Intel Xeon processor E5420, 2.5GHz, 12 MB L2 cache,
1333MHz FSB, 80w
Memory
8 GB PC2-5300 CL5 ECC DDR2 Chipkill FB DIMM 667MHz
Disk
2 x 73 GB 3.5-inch SAS, 15000 RPM, hot swap; RAID-1 mirrored using
IBM ServeRAID 8k-l SAS controller (hardware RAID-1)
AC power
2 x 670W A/C Power Supply (redundant, hot-swap); 2.8m, 100-240V,
C13 to IEC 320-C14 (WW) rack power cable
DC power
2 x 670W D/C Power Supply (redundant; hot swap); 2.8m, 100-240V,
C13 to IEC 320-C14 (WW) rack power cable
Remote management
Remote Supervisor Adapter II (RSA-II) Slimline with external RJ-45
Ethernet port (internal PCI card)
Optical drive
DVD/CD-RW
Cooling
Two fans per CPU, one fan per power supply
Networking
2 x 10/100/1000 Mbps
Serial
COM1, DB-9
Rail kit
Pizarro (Nortel-specified)
Mount the hardware
The AS 5300 server requires the Pizzaro rail kit for rack-mount
installations.
Mounting the server
Use this procedure to mount the physical server into a server rack.
Prerequisites
•
You require a Pizzaro rail kit for each IBM x3550 server being installed.
Procedure Steps
Step
Action
1
Adjust the rail kit to fit in the frame. To properly support the
server, each rail must be mounted to the outside of the front and
rear of the frame.
2
Adjust the left and right rails by sliding the rear mounting bracket
to fit the frame.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300
01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.