72 Troubleshooting

CTA 500

dm On Line Guide

P0873832 Issue 05

¥

If the cable is faulty or the ICS is down, the attached phone will
also not work.

AT command problem?

The CTA 500

dm does not respond to AT commands sent from

your PC.
¥

Make sure that your PC, terminal or other DTE is conÞgured
correctly.

¥

Check the DTE connection. If the DTE is conÞgured as a DCE
you may need a null modem cable.

¥

Check that your PC or DTE is conÞgured to expect CD and CTS
signals. See

ÒSerial Interface Control LinesÓ on page 56

for

more information.

¥

Check that the CTA 500dm is in the command mode.

¥

Check that your PC or DTE is conÞgured to provide a DTR
signal. See

ÒSerial Interface Control LinesÓ on page 56

for more

information.

¥

If the LED is ßashing quickly, refer to the

ConÞguration

section

of this document.

¥

Check that the CTA 500dm serial port is set to the correct baud
rate (115200 is required for all cases except during a software
upgrade) using

ÒSerial Interface RateÓ on page 54

.

Echoed AT commands from the CTA 500

dm do not appear

correctly on your PC, but the response messages appear
correctly.
¥

Check the echo option on your PC.

¥

Disable echo if your PC displays duplicate characters. Enable
echo if your PC does not display any characters.

¥

See

ÒSet Local EchoÓ on page 38

for more information.

AT response messages do not appear correctly on your PC but
AT commands appear correctly.
¥

If numbers are being returned to the PC instead of messages,
change the message code setting on the CTA 500dm. See

ÒVerbose ControlÓ on page 40

for more information. The

numeric responses and indications are shown in

ÒNumeric

CTA 500dm responsesÓ on page 83

.

¥

Make sure that your terminal is operating in full duplex mode
rather than half duplex mode.