Load stored profile, Load stored profile on start-up – Nortel Networks CTA 500dm User Manual
Page 31
AT commands 31
P0873832 Issue 05
CTA 500
dm On Line Guide
Load Stored Profile
The Load Stored ProÞle Command
Z[value]
or
&F[value]
instructs the CTA 500dm to load all values that are stored in a
proÞle. Value 0 indicates that the factory proÞle should be loaded.
Value 1 indicates that the user proÞle should be loaded.
Any calls in progress are disconnected when you use this command.
The Z command selects the user proÞle (default value 1).The &F
command selects the factory proÞle (default value 0). Using either
command, if no value is speciÞed, the default proÞle is used.
Result Codes
OK Appears when the command is executed.
ERROR Appears when the command could not be executed.
Load Stored Profile on Start-up
The Load Stored ProÞle on Start-up Command
&Y[value]
instructs the CTA 500dm to load all values that are stored in a proÞle
after a power-up or after a DTR reset if &D is set to 3 (see
Interface Control LinesÓ on page 56
for the commands).
Value 0 indicates that the factory proÞle should be loaded at start-up.
Value 1 indicates that the user proÞle should be loaded at start-up. If
no value is speciÞed, the default factory proÞle is used.
Result Codes
OK Appears when the value is recognized or not supplied.
ERROR Appears when the value is invalid or unrecognized.