beautypg.com

Hook command, Outgoing call control, Outgoing call control commands summary – Nortel Networks CTA 500dm User Manual

Page 47: Outgoing call bearer service control

background image

AT commands 47

P0873832 Issue 05

CTA 500

dm On Line Guide

Hook Command

The Hook Command

H

instructs the CTA 500dm to disconnect from the current call.

Result Code

OK Appears upon completion of the command. DCD is dropped
immediately before the indication if &C is 1 (see

ÒSerial Interface

Control LinesÓ on page 56

for more details).

Outgoing Call Control

Calls processed by the CTA 500dm can use any of three ISDN
bearer services. Additionally, the data rate over each of these bearer
services can be set to either 56 kbit/s or 64 kbit/s. See

ÒBearer

CapabilitiesÓ on page 81

for more information.

Outgoing Call Control commands summary

Outgoing Call Bearer Service Control

The Outgoing Call Bearer Service Control Command

%A98=value

controls the type of bearer service used by the CTA 500dm for
making outgoing calls. Not all bearer services are available to all
users; however, all bearer services are usually available on an ICS
that has an ISDN connection to the network.

Command

Description

Value

%A98=n

set outgoing call type

0 data bearer service (default)
1 3.1 kHz audio bearer service
2 speech bearer service

%A4=n

select speed of TCM

channels, outgoing calls

0 64 kbit/s
1 56 kbit/s (default)