beautypg.com

Fault tracing 85(86) – Nx Networks NX series User Manual

Page 85

background image

Fault tracing

85(86)

9

14

Frequency
converter over
temperature

Heatsink temperature is over 90

°

C.

Over temperature warning is issued when
the heatsink temperature exceeds 85

°

C.

Check the correct amount and flow of
cooling air.
Check the heatsink for dust.
Check the ambient temperature.
Make sure that the switching frequency
is not too high in relation to ambient
temperature and motor load.

15

Motor stalled

Motor stall protection has tripped.

Check motor.

16

Motor
overtemperature

Motor overheating has been detected by
frequency converter motor temperature
model. Motor is overloaded.

Decrease the motor load.
If no motor overload exists, check the
temperature model parameters.

17

Motor underload

Motor underload protection has tripped.

22
23

EEPROM
checksum fault

Parameter save fault

faulty

operation

component

failure

24

Changed data
warning

Changes may have occurred in the
different counter data due to mains
interruption

No special actions required. Take a
critical attitude to the counter data.

25

Microprocessor
watchdog fault

faulty

operation

component

failure

Reset the fault

and restart.

Should the fault re-occur, contact your
nearest distributor.

32

Fan cooling

Cooling fan of the frequency converter
does not start, when ON command is
given

Contact your nearest distributor.

34

CAN bus
communication

Sent message not acknowledged.

Ensure that there is another device on
the bus with the same configuration.

36

Control unit

NXS Control Unit can not control NXP
Power Unit and vice versa

Change control units

37

Device change

Option board changed.
Different power rating of drive.

Reset

38

Device added

Option board added.
Drive of different power rating added.

Reset

39

Device removed

Option board removed.
Drive removed.

Reset

40

Device unknown

Unknown option board or drive.

41

IGBT temperature

IGBT Inverter Bridge overtemperature
protection has detected too high a short
term overload current

Check loading.
Check motor size.

42

Brake resistor
overtemperature

Brake resistor overtemperature protection
has detected too heavy braking

Set the deceleration time longer.
Use external brake resistor.

43

Encoder fault

Note the exceptional Fault data record.
See 7.3.4.3. Additional codes:
1 = Encoder 1 channel A is missing
2 = Encoder 1 channel B is missing
3 = Both encoder 1 channels are missing
4 = Encoder reversed

Check encoder channel connections.
Check the encoder board.

50

Analogue input
I

in

< 4mA

(selected signal
range 4 to 20
mA)

Current at the analogue input is < 4mA.

control cable is broken or loose

signal source has failed

Check the current loop circuitry.

51

External fault

Digital input fault.

52

Keypad
communication
fault

The connection between the control
keypad and the frequency converter is
broken.

Check keypad connection and possible
keypad cable.

Table 9-1. Fault codes