Nx Networks NX series User Manual
Page 33
Cabling and connections
33(86)
6
5
Connect the cables:
!
Strip the motor and mains cables as advised in Table 6-3 and
Figure 6-3.
!
Remove the screws of the cable protection plate.
!
Make holes into and pass the cables through the rubber
grommets on the bottom of the power unit (see e.g. Figure 6-7).
!
Connect the mains, motor and control cables into their
respective terminals (see e.g. Figure 6-7).
!
For information on the installation of larger units, please contact
your local distributor.
!
For Information on cable installation according to UL
regulations see Chapter 6.1.3.
!
Ensure that the control cable wires do not come in contact with the
electronic components of the unit.
!
If
an
external brake resistor (option) is used, connect its cable to
the appropriate terminal.
!
Check the connection of the earth cable to the motor and the
frequency converter terminals marked with
.
!
Connect
the
separate shield of the power cable to the earth
terminals of the frequency converter, motor and the supply centre.
!
Attach the cable protection plate with the screws.
!
Ensure that the control cables or the cables of the unit are not
trapped between the frame and the protection plate.