Nx Networks NX series User Manual
Page 62
62(86)
Control keypad
7
7.3.4.3 Fault time data record
When a fault occurs the information described above in 7.3.4 is displayed. By pushing the
right
arrow menu button
it is possible to view the Fault time data record menu indicated by T.1
#
#
#
#
T.13.
In this menu, some selected important data valid at the time of the fault are recorded. This feature
is intended to help the user or the service person to determine the cause of fault.
The data available are:
T.1
Counted operation days
(Fault 43: Additional code)
d
T.2
Counted operation hours
(Fault 43: Counted operation days)
hh:mm:ss
(d)
T.3
Output frequency
(Fault 43: Counted operation hours)
Hz
(hh:mm:ss)
T.1
Counted operation days
d
T.2
Counted operation hours
hh:mm:ss
T.3
Output frequency
Hz
T.4
Motor current
A
T.5
Motor voltage
V
T.6
Motor power
%
T.7
Motor torque
%
T.8
DC voltage
V
T.9
Unit temperature
°
C
T.10
Run status
T.11
Direction
T.12
Warnings
T.13
0-speed
Table 7-4. Fault time recorded data