You can connect the power supply to a power bar. The total length of the power cables from
the power supply to the electrical outlet (including power bar) must not exceed 2 m (6.5 ft).
You must use a power bar approved by an appropriate National Test Body, with a third-wire
ground. Nortel recommends that you do not use an extension cord between the power supply
and the power bar or between the power bar and the electrical outlet.
•
You cannot install the BSG unit behind another router. If you install the BSG behind another
router, it may not operate properly with SIP traffic.
•
You must meet the following parameters for an analog telephony devices (analog loop):
— maximum DC loop resistance of 208
Ω
— maximum cable length (0.5 mm or 24-AWG) of 1220 m (4000 ft)