You can connect the power supply to a power bar. The total length of the power cables from
the power supply to the electrical outlet (including power bar) must not exceed 2 m (6.5 ft).
You must use a power bar approved by an appropriate National Test Body, with a third-wire
ground. Nortel recommends that you do not use an extension cord between the power supply
and the power bar or between the power bar and the electrical outlet.

You cannot install the BSG unit behind another router. If you install the BSG behind another
router, it may not operate properly with SIP traffic.

You must meet the following parameters for an analog telephony devices (analog loop):
— maximum DC loop resistance of 208

Ω

— maximum cable length (0.5 mm or 24-AWG) of 1220 m (4000 ft)