A-18 Host error messages
555-9001-316 Standard 1.0 February 1996
ERR: reset action xx of the action xxx not found
Meaning:
The reset action template xx defined in the action template
xxx was not found under the 3270 directory.
Action to take:
Create the appropriate reset template file.
ERR: logout action xx of the action xxx not found
Meaning:
Logout action xx defined in the action template xxx was not
found under the 3270 directory.
Action to take:
Create the appropriate logout template file.
ERR: Unable to find ACTION xx
Meaning:
Action template file xx was missing from the 3270
directory.
Action to take:
Create the appropriate action template file.
ERR: Unable to open Information Logger
Meaning:
TRS was unable to open trs.log file.
Action to take:
Check the permissions of the trs.log file.
ERR: Buffer size is greater than xx
Meaning:
The entry exceeds the maximum buffer size xx.
Action to take:
Contact your Nortel service representative.
ERR: No row/column delimiter for screen template
Meaning:
Syntax error in row/column field defined in the screen
template file.
Action to take:
Revise the screen template file and make sure there is a
comma between the row and column so that the format is
‘row, col’.
ERR: Set_timer: Error setting interval timer struct
Meaning:
TRS got an operating system error when it was trying to set
a timer.
Action to take:
Contact your Nortel service representative.