beautypg.com

Table 5-2. ni-daqmx rtd measurement properties – National Instruments Module SCXI-1503 User Manual

Page 48

background image

Chapter 5

Using the SCXI-1503

© National Instruments Corporation

5-5

SCXI-1503 User Manual

Analog Input»General
Properties»Advanced»
Gain and Offset»Gain
Value

AI.Gain

Specifies a gain factor to apply
to the signal conditioning
portion of the channel. The
SCXI-1503 supports 1 or 100.

No

Analog Input»General
Properties»Advanced»
High Accuracy Settings»
Auto Zero Mode

AI.AutoZeroMode

Specifies when to measure
ground. NI-DAQmx subtracts
the measured ground voltage
from every sample. The
SCXI-1503 supports None or
Once.

Yes

Analog Input»General
Properties»Advanced»
Input Configuration»
Coupling

AI.Coupling

Specifies the input coupling of
the channel. The SCXI-1503
supports DC and GND
coupling.

No

Table 5-2. NI-DAQmx RTD Measurement Properties

Property

Short Name

Description

DAQ

Assistant

Accessible

Analog Input»Temperature»
RTD»Type

AI.RTD.Type

Specifies the type of
RTD connected to the
channel.

Yes

Analog Input»Temperature»
RTD»R0

AI.RTD.R0

Specifies the
resistance in ohms of
the sensor at 0

°C.

Yes

Table 5-1. NI-DAQmx Voltage Measurement Properties (Continued)

Property

Short Name

Description

DAQ

Assistant