Example, Defining fields 4-7 – Paxar Monarch 9413 User Manual
Page 55
Example
T,2,10,V,250,50,0,1,1,1,B,C,0,0,0
p
Defines a text field (field #2) with a variable length of up to 10
characters. The field begins at row 250, column 50. There is no
additional gap between characters, and the Standard font is used
without any additional magnification. The printing is black on
white and centered. No field or character rotation is used. The
internal symbol set is used.
D e f i n i n g B a r C o d e F i e l d s
Each bar code field requires a separate definition.
Syntax
B,field#,# of char,fix/var,row,column,
font,density,height,text,alignment,
field rot
p
B1. B
Bar Code Field.
B2. field#
Unique number from 0-999 to identify this field.
B3. # of char
Maximum number of characters. If the bar code uses a check
digit, allow an extra character for the check digit. The actual
maximum number of characters is limited by the size of the
label and bar code density. Range: 0-2710.
B4. fix/var
Fixed (F) or variable (V) length field.
Bar Code
Number of Characters
Fixed/Variable
UPCA
12
F
UPCA+2
14
F
UPCA+5
17
F
UPCE
7
F
UPCE+2
9
F
UPCE+5
12
F
EAN8
8
F
EAN8+2
10
F
EAN8+5
13
F
EAN13
13
F
EAN13+2
15
F
Defining Fields 4-7