beautypg.com

Paxar Monarch 9413 User Manual

Page 37

background image

Be careful when using this feature. If you forget what the control
characters were changed to, print a test label. The test label lists
the current control characters. See "Printing a Test Label," in
Chapter 8 for more information.

D e f i n i n g t h e C o m m u n i c a t i o n S e t t i n g s P a c k e t

Use the communication settings packet (F) to set the baud rate,
word length, stop bits, parity, and flow control for serial
communications. To set parallel communications, see "Using
Parallel Communications." Changing the communication settings
takes approximately two seconds. Communications sent during
this interval will be lost. Make sure the host communication
values match the values on the printer.

Syntax

{

I

,F,baud,word_length,stop_bits,parity,

flow_control

p

}

F1. F

Communication Settings Packet

F2. baud

Baud Rate. Options:

0 1200

3 9600 (default for all printers)

1 2400

4 19200

2 4800

5 38400

F3. word_length

Word Length. Options:

0

7-bit word length

1

8-bit word length (default for all printers)

F4. stop_bits

Stop Bits. Options:

0

1-stop bit (default for all printers)

1

2-stop bits

F5. parity

Parity. Options:

0

None (default for all printers)

1

ODD parity

2

EVEN parity

F6. flow_control

Flow Control. Options:

0

None

2

(CTS)

1

DTR (default

3

XON/XOFF

for all printers)

NOTE:

If you use the DOS COPY command to download
your formats, set "Flow Control" to DTR (not
XON/XOFF).

Configuring the Printer 3-15