C. Technical Specifications
C-2
January 2004
4200-A2-GN20-40
Interfaces
GranDSLAM 4200:
DSL PORTS: 50-pin RJ21X Telco-type connector
POTS: 50-pin RJ21X Telco-type connector
CONSOLE: DB9 (EIA-232-E)
MGMT: 8-pin modular jack (10/100BaseT)
4201 T1 Uplink Module:
100
Ω: RJ48C connector
4202 E1 Uplink Module:
TX/RX 75
Ω: BNC connector
120
Ω: RJ48C connector
4203 T1/E1 IMA Uplink Module:
1
−8 RJ48C connectors
– T1: 100
Ω impedance
– E1: 120
Ω impedance
NEBS
The GranDSLAM 4200 is Network Equipment-Building System (NEBS)
certified.
Operating
Environment
Ambient Temperature: –40
° to 65° C (–40° to 149° F)
Relative Humidity: 5% to 95% noncondensing
Storage Temperature: –40
° to 85° C (–40° to 185° F)
Shock and vibration tolerance sufficient to withstand normal shipping
Physical
Dimensions
Height: 1.75
″ (44.5 mm, or 1U as defined in EIA-310-C) without feet
Width: 17.2
″ (436.9 mm) without mounting brackets
Depth: 11.8
″ (299.7 mm)
Weight: 8.5 lb (3.9 kg) without POTS splitter
9.6 lb (4.4 kg) with 600-Ohm POTS Splitter
10.4 lb (4.7 kg) with 900-Ohm POTS Splitter
Power
The unit operates from a standard CO –48 VDC power supply (–40.5
to –57.0 VDC). Dual feeds are supported. The terminal block accepts
28 to 18 AWG bare wire. The unit has two replacable, external fuses
with a visual spring indicator and an alarm in case the fuse is blown.
Power
Consumption
Model 4210:
–48 VDC, 3.5 Amps maximum sustained overcurrent protection,
30 Watts typical, 32 Watts maximum
Models 4220 and 4230:
–48 VDC, 4 Amps maximum sustained overcurrent protection,
48 Watts typical, 53 Watts maximum
Table C-1.
GranDSLAM 4200 Technical Specifications (2 of 2)
Specifications
Criteria