4202 e1 uplink module connectors, 120w connector, 75w tx/rx connectors – Paradyne IP DSLAM GranDSLAM 4200 User Manual
Page 59
A. Connectors and Pin Assignments
4200-A2-GN20-40
January 2004
A-7
4202 E1 Uplink Module Connectors
The 4202 E1 Uplink Module has two types of connectors, only one of which may
be used at a time:
120
Ω Connector
75
Ω Connector TX/RX Connectors
120
Ω Connector
The 120
Ω connector is a single, RJ48C, unkeyed, shielded, 8-pin modular jack.
The shield is connected to ground via the module. Pin assignments for the 120
Ω
.
75
Ω TX/RX Connectors
The 75
Ω TX/RX connectors each use coaxial cables that are unbalanced with
respect to ground. The shield of the TX cable is connected directly to ground at the
E1 module. The shield of the RX cable is capacitor-coupled to ground at the
module. Pin assignments for the 75
Ω TX/RX connectors are shown in
.
Table A-7.
4202 E1 Uplink Module 120
Ω Connector
Signal
Direction
Pin
Receive Ring
In
1
Receive Tip
In
2
NC
—
3
Transmit Ring
Out
4
Transmit Tip
Out
5
NC
In
6
NC
—
7
NC
—
8
Table A-8.
4202 E1 Uplink Module 75
Ω TX/RX Connectors
Signal
Direction Pin
Transmit
Out
Coax Center Conductor
Transmit Signal and Chassis Ground —
Barrel
Receive
In
Coax Center Conductor
Receive return path (not grounded)
Out
Barrel