Voltage

Minimum tolerance = -38VDC

Nominal rating = -48 to -60VDC

Maximum tolerance = -75VDS

Maximum input current = 17.0 Amps
The power supply will power-off if the DC input is less than -34 VDC.

DC Power Supply LED Indicators

AC Power Supply Interface Requirements

The AC power supply operates within the following limits:

AC line voltage = Auto-ranging for either 100-127 VAC or 200-240 VAC

AC line frequency = 50/60 Hz

AC input current = 4 Amp at 100-127 VAC, 2 Amp at 200-240 VAC

AC Power Supply LED Indicators

Power Supply condition

Power Supply LED

No DC power to all PSUs

Off

No DC power to this PSU only

Amber

DC present/Only Standby Outputs On

Blink Green

Power supply DC outputs ON and OK

Green

Current limit

Amber

Power supply failure

Amber

Power Supply condition

Power Supply LED

No AC power to all PSUs

Off

No AC power to this PSU only

Amber

DC present/Only Standby Outputs On

Blink Green

Power supply DC outputs ON and OK

Green

Power supply in Alert Condition

Blink Amber

Power supply failure

Amber