Ser_flow rs-232 flow control, Description, System parameters – Polycom C16 User Manual
Page 456: Dev_bootloader_ver bootloader version, Examples
Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 114
ser_flow RS-232 Flow Control
Description
This parameter sets the type of flow control that will be used on the RS-232
port. Hardware flow control is recommended for baud rates over 9600 bps.
Examples
System Parameters
dev_bootloader_ver Bootloader Version
Description
This parameter returns the bootloader version.
Argument
Argument value
Channel Type
Device-Specific System
Value Type
List
Read/Write Mode
Read/Write
Values
none : No flow control (default)
hw : Hardware flow control (RTS/CTS)
Command
Response
Description
set ser_flow 1 hw
val ser_flow 1 hw
Sets the serial port flow control on device 1 (the first
device) to 'hw'.
set ser_flow 1 none
val ser_flow 1 none
Disables the serial port flow control on device 1 (the first
device) by setting the flow control to 'none'.
Argument
Argument value
Channel Type
Device-Specific System
Value Type
String
Read/Write Mode
Read-Only
System Limits
Max String Length: 24