beautypg.com

Hardware troubleshooting, Hardware troubleshooting –16 – Polycom C16 User Manual

Page 324

background image

Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12

10 - 16

SoundStructure Studio Can’t Find My SoundStructure Device Over Ethernet

Depending on network router configurations, SoundStructure Studio may

only be able to find devices that are connected to the same subnet as the local

PC that is running SoundStructure Studio. Ensure your PC or control system

is on the same subnet as the SoundStructure device.
If on the same subnet and you still can’t find the SoundStructure device with

SoundStructure Studio, make sure the SoundStructure device is connected to

the ethernet and has either received an IP address from a DHCP server, or has

a static IP address that has been set and doesn’t conflict with any other devices

on the network. If the DHCP lease has expired or the IP address has changed,

it make take a minute or so for the SoundStructure Studio to be able to find the

SoundStructure device.

Hardware Troubleshooting

SoundStructure devices have built-in diagnostics that are designed to isolate

configuration issues from hardware issues. If the system is not operating

according to expectations, the first step is to check the SoundStructure

front-panel LED.
The SoundStructure front-panel LED indicates the status of the device as

shown in following table. The different states of the SoundStructure

front-panel LED are shown in this table.

If the front-panel LED is green, then the hardware is operating correctly.
If there is a yellow LED on the front-panel, there is information in a Sound-

Structure system log that should be reviewed. The LED could be yellow for a

variety of reasons including the design file is expecting a telephony plug-in

card but there isn’t one installed in the device.
If there is a red LED on the front-panel, it is possible there is a software or hard-

ware issue with the device that may require a firmware update. Check the logs

and then contact tech support.

LED

Color

State

Description

Flashing The system is starting up.

Solid

The system is operating
normally.

Yellow

Solid

The system has logged a
warning and the system
logs should be reviewed.

Red

Solid