Phantom 48 v phantom power, Description, Safety_mute safety mute – Polycom C16 User Manual
Page 376: Examples
Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 34
phantom 48 V Phantom Power
Description
Enables or disable phantom power on mic inputs. Setting phantom to 1 enables
phantom power, while setting it to 0 disables phantom power.
Examples
safety_mute Safety Mute
Description
This parameter sets the status of the safety mute. If safety mute is enabled (1),
all line outputs of all the devices are muted.
Examples
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Boolean
Read/Write Mode
Read/Write
Phys Chans
Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans
Mono, Stereo
Default
0
Command
Response
Description
set phantom "Table
Mic 1" 1
val phantom "Table
Mic 1" 1
Enables the 48V phantom power supply for the input channel
"Table Mic 1".
Argument
Argument value
Channel Type
Global System
Value Type
Boolean
Read/Write Mode
Read/Write
Default
0
Command
Response
Description
set safety_mute 1
val safety_mute 1
Enables the safety_mute for a SoundStructure system.
set safety_mute 0
val safety_mute 0