beautypg.com

Phantom 48 v phantom power, Description, Safety_mute safety mute – Polycom C16 User Manual

Page 376: Examples

background image

Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12

A - 34

phantom 48 V Phantom Power

Description

Enables or disable phantom power on mic inputs. Setting phantom to 1 enables

phantom power, while setting it to 0 disables phantom power.

Examples

safety_mute Safety Mute

Description

This parameter sets the status of the safety mute. If safety mute is enabled (1),

all line outputs of all the devices are muted.

Examples

Argument

Argument value

Channel Type

Virtual Channel

Value Type

Boolean

Read/Write Mode

Read/Write

Phys Chans

Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input

Virt Chans

Mono, Stereo

Default

0

Command

Response

Description

set phantom "Table
Mic 1" 1

val phantom "Table
Mic 1" 1

Enables the 48V phantom power supply for the input channel
"Table Mic 1".

Argument

Argument value

Channel Type

Global System

Value Type

Boolean

Read/Write Mode

Read/Write

Default

0

Command

Response

Description

set safety_mute 1

val safety_mute 1

Enables the safety_mute for a SoundStructure system.

set safety_mute 0

val safety_mute 0

Turns off the safety_mute for a SoundStructure system.