Command Protocol Reference Guide

A - 27

Acknowledgements are generated when either a parameter command is

issued or a parameter changes value for some other reason. When a parameter

command is executed with the get action, the acknowledgement is only sent to

the control interface that the parameter command was received from.

When a parameter command is executed with the set, inc, dec, or tog actions,
then if the action results in the parameter changing value, the

acknowledgement is sent to all control interfaces on all devices, otherwise (if

the action doesn’t change the value of the parameter) the acknowledgement is

sent only to the control interface that the parameter command was received

on. When a parameter changes state for any reason (for example, command

execution, logic pin operations, etc.) an acknowledgement is sent to all

interfaces on all devices.
As an example, consider the fader command, and assume a Mic Input mono

virtual channel has been defined with the label “Microphone 1”. Also assume

the current value of the fader parameter for that channel is 3. If a control

program connected to any control interface of the SoundStructure device

sends the following command:

set fader "Microphone 1" 6.0

then the following acknowledgement will be generated,

val fader "Microphone 1" 6.0

This acknowledgement will be sent to all control interfaces on all

SoundStructure devices. Now, if the control program sends this command:

get fader "Microphone 1"

then the following acknowledgement will be generated,

val fader "Microphone 1" 6.0

but this acknowledgement will only be sent to the specific device and control

interface that the control program is communicating through.
This implementation of the command protocol has been designed with these

frugal acknowledgments because some control systems have limited buffer

sizes that are susceptible to buffer overflows when large amounts of data

traffic are generated that the particular control port didn’t request.

Warning

When a parameter command is executed with the get action, the acknowledgement
is only sent to the control interface that the parameter command was received from.

This manual is related to the following products: