am_hold_time Automixer Hold Time
Description
This parameter defines how long (in ms) the microphone in the specified
automixer group will be considered active after the last detected significant
level on the microphone.
am_last_mic_mode Automixer Last Mic Mode
Description
When this parameter is set to 1, the last mic mode is enabled on the
microphone.
Command
Response
Description
set am_group "Table Mic
1" 1
val am_group "Table Mic
1" 1
Assigns "Table Mic 1" to automixer group 1.
Argument
Argument value
Channel Type
Global Systems
Value Type
Integer
Read/Write Mode
Read/Write
Indices
1-63 : group number
Systems Limits
Minimum: 10, Maximum: 10000
Default
500
User Limits
Supported
No
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Boolean
Read/Write Mode
Read/Write
Phys Chans
Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans
Mono, Stereo
Default