4.7.5.3 Hardware Temperature
This page allows you to:
view current system temperature
set several temperature and time thresholds (see description in the following table)
From the Maintenance menu, click on Fault Management and then Hardware Temp. The
following page is displayed:
Temperature Configuration
Label
Description
Modify
Click on this button to submit the update once you have entered all
the new threshold values.
Current Temperature (
o
C)
This field shows the current system temperature.
Up Shift Threshold (
o
C)
The system will produce notification (alarm) when the monitored
system temperature is higher than Up Shift Threshold (-55~85
o
C) for
over Up Shift Time (1~255 sec).
Up Shift Time (Sec)
Refer to the description for Up Shift Threshold.
Down Shift Threshold (
o
C)
The system will produce notification (alarm) when the monitored
system temperature is lower than Down Shift Threshold (-55~85
o
C)
for over Down Shift Time (1~255 sec).
Down Shift Time (Sec)
Refer to the description for Down Shift Threshold.
Fan ON Threshold (
o
C)
FAN Enable temperature threshold (-40~15
o
C). When the system
temperature is higher than the threshold, the fan will be turned on
automatically.
Fan Shift Time (Sec)
This field shows the elapsed time since the FAN was turned on.