Models 3151/3161 Interface Connections

B-7

3000-A2-GA31-80

December 1994

DSX-1 Port DTE Interface

This cable is typically supplied by a DTE vendor and is

a 22 AWG solid, individually shielded twisted pair cable
with drain wire (see Figure B-4). The cable connector is a
DB15 plug. Be sure to connect the shield ground only at
the DSU/CSU end as shown in Figure B-4 to prevent

ground loops. The DTE (DSX-1) interface connector is a
DB15-type socket connector (see Table B-3). Refer to the
Extrn DLB configuration option in the DTE Interface
Options
section in Appendix B of the ACCULINK 315x
Channel Service Unit Operator’s Guide
or the
ACCULINK 316x Data Service Unit/Channel Service Unit
Operator’s Guide
for more information.

Figure B-4. DTE (DSX-1) Cable

Table B-3

DTE (DSX-1) Interface Connector (J3)

Signal

Pin Number

Receiver Tip from DTE

1

Receiver Ring from DTE

9

Transmitter Tip to DTE

3

Transmitter Ring to DTE

11

Relay Contact Sense Return

12

Relay Contact Sense

14

Shield Ground

2, 4