Precision Trading 60 R3.0 User Manual
Page 48
![background image](/manuals/176805/48/background.png)
Operator Manual, Supercharger 60
R3.0
Page 48 of 62
Figure 9 - Monitor Board Adjustments
9.2.4.
MONITOR (see fig 12)
NOTE:
Use pin 14 on the card connector (or the Test Point E0 on the
Control Board) as ground reference for voltage measurements.
9.2.4.1. U12 pin 1 - BATTERY VOLTAGE
• This point corresponds to one tenth of the battery voltage present
at the input terminals.
9.2.4.2. U12 pin 7 - CELL SELECTOR
•
This point corresponds to one tenth volt per cell,
e.g. 2.00V = 20
cells.