Precision Trading 60 R3.0 User Manual
Page 12
Operator Manual, Supercharger 60
R3.0
Page 12 of 62
3. SPECIFICATIONS
3.1 CHARGE
3.1.1. CONTROL: SCR, air cooled.
3.1.2. MAXIMUM CURRENT: 50 AMPS.
3.1.3. MINIMUM INCREMENT: 0.1 AMP.
3.1.4. ACCURACY and STABILITY of settings: ±1% of reading, ±0.1 AMP.
3.1.4.1. FLOAT:
• The reference voltage is set at the equivalent of 2.33V/cell (Lead-
Acid).
• The Cell Selector provides the basic reference as nominal battery
voltage, e.g.: a 24V battery is entered as 24 on the Cell Selector.
• Current reduction from within 0.5V of the float voltage, with an
accuracy of ±0.5%, ±0.1A
3.1.4.2. PEAK:
• The reference voltage is set at the equivalent of 2.45V/cell (Lead-
Acid).
• The Cell Selector provides the basic reference as nominal battery
voltage, e.g.: a 24V battery is entered as 24 on the Cell Selector.
• Voltage transfer or stop within " 1% of the Peak Voltage.
• Note: Due to cable/connector losses the peak voltage registered by
the Charger-Analyzer will be higher than the actual battery voltage
(up to 0.2V depending on current).