• NOTE 1: Other currents can also be used for High

Current calibration (20A minimum).

• NOTE 2: Adjustments of R28 and R25 are

interactive. Therefore, It will be necessary to repeat
the adjustments once or twice to achieve exact
results.

• The Voltage reading at E3 (shunt amplifier output)

must correspond to the current as follows: voltage at
E3 = -0.1V/A ±2%.

• Examples:

40 A equals -4.00V ±0.08V

20 A equals -2.00V ±0.04V

10 A equals -1.00V ±0.02V

5 A equals -0.50V ±0.01V

Figure 8 - Current Control Board Adjustments