CONTROLS AND DISPLAYS

4.1 M1 - Ammeter

4.1.1. 0 to 199.9ADC DIGITAL PANEL METER.

4.1.2. Positive sign indicates charge current.

4.1.3. Minus sign indicates discharge current.

4.2 M1 - Voltmeter

4.2.1. 0 to 1.999VDC, 0 to 19.99VDC and 0 to 199.9VDC DIGITAL PANEL METER.

4.2.2. Indicates battery voltage in the internal (20/200V) position and voltage present at

the RED (+) and BLK (-) jacks in the 2/20/200V external positions. Positive sign
indicates proper battery connection. Minus sign indicates reversed polarity
connection.

4.3 R1 - Main Charge Current Selector

4.3.1. Ten turn potentiometer with digital readout to program: current

4.3.1.1. MAIN charge current, 0 to 50.0 AMPS.

4.4 R2 - Topping/Discharge Current Selector

4.4.1. Ten turn potentiometer with digital readout to program:

4.4.1.1. TOPPING charge current, 0 to 50.0 AMPS

4.4.1.2. DISCHARGE current, 0 to 60.0 AMPS

4.5 SW1 - Main Time selector switch

4.5.1. 0 to 9 hours (or minutes), to determine the duration of the main charge.

4.6 SW2 - Total Time selector switch

4.6.1. 0 to 60 hours (or minutes), to determine the total charge or discharge duration.

4.7 SW3 – Keypad

Five station membrane push button control switch to select and control the mode of
operation, as follows:

4.7.1. GREEN: Stop/reset, cycle end.

4.7.2. WHITE: Two rate charge mode (main and topping).

4.7.3. YELLOW: Single rate charge mode.

4.7.4. BLUE: Auto cut-off discharge (analysis).

4.7.5. RED: Full discharge (deep cycle).