beautypg.com

Precision Trading 60 R3.0 User Manual

Page 26

background image

Operator Manual, Supercharger 60

R3.0

Page 26 of 62

5.4 DISCHARGE.

NOTE: For battery voltages greater than 32V, the discharge current is automatically
limited to 30A. A current fault condition will result if more than 30A is programmed.

5.4.1. ANALYSIS (AUTO CUT-OFF):

5.4.1.1. The battery is discharged at the selected rate for a preset time.

5.4.1.2. Discharge is automatically terminated (cycle end), at the end of the

time selected or if the battery voltage reaches the equivalent of 1
VOLT/cell (capacity failure), as determined by the number of cells
programmed, or it is terminated as a fault, if:

• The actual discharge current differs from the programmed value by

more than 1 AMP (current fault).

• Overheating of the transistor heat sinks is detected (overheat fault).
NOTE: Discharge operation can be terminated at any time by

depressing the (green) reset button.

5.4.2. DEEP CYCLE (FULL DISCHARGE):

5.4.2.1. The battery is discharged at the selected rate for a preset time.

5.4.2.2. Discharge is automatically terminated (cycle end) at the end of the time

selected, or as a fault, if:

• The actual discharge current differs from the programmed value by

more than 1 AMP (current fault). NOTE: Undercurrent fault
monitoring is disabled at battery voltages below 2V.

• Overheating of the transistor heat sinks is detected (overheat fault).