beautypg.com

Precision Trading 60 R3.0 User Manual

Page 23

background image

Operator Manual, Supercharger 60

R3.0

Page 23 of 62

5.

MODES OF OPERATION

5.1 CONSTANT CURRENT CHARGE

5.1.1. DUAL RATE:

5.1.1.1. The battery is charged at the main rate for a preset time, at the end of

which, the current is switched automatically to the topping rate for the
remainder of the total time selected.

5.1.1.2. Charging is automatically terminated at the end of the total time

selected (cycle end), or as a fault if:

• Battery overtemperature is detected (Overtemp fault).
• Battery voltage is in excess of 1.75V/cell as determined by the

number of cells programmed, or if battery voltage is in excess of
85V (voltage fault).

• Actual charging current differs from the programmed value by

more than 1 AMP (current fault).

5.1.1.3. Charge operation may be terminated at any time by depressing the

RESET (green) button.

5.1.2. SINGLE RATE:

5.1.2.1. The battery is charged at the topping rate for a preset time.

5.1.2.2. Charging is automatically terminated at the end of the total time

selected (cycle end), or as a fault if:

• Battery overtemperature is detected (Overtemp fault).
• Battery voltage is in excess of 1.75V/cell as determined by the

number of cells programmed, or if battery voltage is in excess of
85V (voltage fault).

• Actual charging current differs from the programmed value by

more than 1 AMP (current fault).

5.1.2.3. Charge operation may be terminated at any time by depressing the

(green) reset button.