Precision Trading 60 R3.0 User Manual
Page 22
Operator Manual, Supercharger 60
R3.0
Page 22 of 62
4.25 DS7B - OVR HEAT:
4.25.1. Indicates that the discharge bank is overheated.
4.26 DS8A - VOLT FLT:
Indicates voltage fault.
4.26.1. Continuous: battery connected with polarity reversed.
4.26.2. Flashing: (during charge) battery voltage in excess of 1.75 volts per cell or in
excess of 85 volts, or open circuit.
4.27 DS8B -CURR FLT:
4.27.1. Indicates that the actual current differs from the programmed value by more than
1A.
4.28 DS9 - CC
4.28.1. Indicates that the charger is in the basic Constant Current mode.
4.29 DS10 - CV
4.29.1. Indicates that the charger is in the Constant Current/Float mode.
4.30 DS11 - PEAK
4.30.1. Indicates that the charger is in the Constant Current/Peak mode.
4.31 AUDIBLE ALARM:
4.31.1. Continuous: turns on with any of the faults.
4.31.2. Pulsating: turns on with cycle end.